It is ADVISABLE to use the filter with metallic BOWL GUARD for enhanced SAFETY requirements to avoid personal injury and/or property damage.

Polycarbonate bowl Should NOT be exposed to synthetic lubricants,alcohols, glycols, liquified petroleum gases or harmful chemicals or their fumes as they can possibly cause the polycarbonate bowl to burst. Use only non-detergent mineral base oils. Clean the bowl with soap and water only. DO NOT use solvents, thinners,acetone or carbon tetra-chloride etc.

Maximum pressure 250 psig. Maximum temperature 50ºC.

It is important to DRAIN THE FILTER BOWL REGULARLY. The liquid level SHOULD NEVER RISE above the baffle.

While servicing the filter, it is ADVISABLE TO CHANGE all the rubber seals. Inspect each part carefully and clean them with water or kerosene only. To clean the sintered bronze filter element,wash in kerosene and blow out with compressed air.

Standard Filters
Install the filter before the regulator and lubricator in the compressed airline, As NEAR As Possible To The POINT OF USE. Where the compressed air is sourced from an overhead line, the air should be piped from the top of the header to the filter. In this way, excessive moisture and dirt are not gravity-fed to the in-line filter. All fittings must be leak tight before applying air pressure to the filter.

Where the filter is not pipe mounted and connected with flexible tubes, the filter should be mounted on the bracket,which is available as spares with your dealer.

For instrument air or other critical applications, we recommend the use of AIRCHAMP COALESCING FILTERS for 99.9% removal of oil, water and dirt.

We have a policy of continual product development and therefore reserve the right to modify products/parts shown in this catalogue, without any notice.

Dimensions Of Standard Filters.
Dimensions & Technical Information About Standard Filters.
CLICK HERE FOR -